● 2 sets of X-ray sources to bring more comprehensive and powerful testing performance
● Flat panel detectors and linear array detectors to meet diversified testing needs
● Spiral scanning and offset scanning to further expand imaging area
● Simple scanning process, rapid reconstruction of imaging and programmable scanning process to ensure the consistency and convenience of batch sample testing
● Dedicated algorithm to enhance image clarity and obtains high-quality image quality
Resolution
Detectability | 30μm | 0.5 μm |
X-ray source
Tube type | Sealed | Open | ||
Voltage | 600KV | 500KV/450KV | 300KV | 240KV/225KV |
Focal spot size* 0.7mm @0.7kW 2.0mm @1.5kW | Focal spot size* 0.4mm @0.7kW 1.0mm @1.5kW | JIMA Resolution 3 μm | JIMA Resolution 2 μm |
Detector (Flat panel)**
Imaging area | 427mm×427mm |
Pixel matrix | 3072×3072 |
Sample
Maximum size | 800mm×1100mm(diameter × height) |
Maximum weight | 100kg |
Equipment
Dimension | 3700mm×2300mm×2800mm(length × width × height) |
Weight | 35000kg~60000kg |
Hardware and software can be configured according to requirements
Focal spot size*: Conforms to EN 12543
Other optional sizes, such as 400mm×400mm, 302mm×249mm etc.